    Not long ago, Schoondoggy asked a few of us to beta test preproduction versions of his drive mount bracket for the HP ProLiant Gen8 MicroServer. Except for the placement of the holes to attach the Schoondoggy Gen8 Drive Mount (“SGDM”) to the PSU – which was easily fixed with my Dremel – the SGDM is perfect in design simplicity coupled with high flexibility. With the SGDM I could mount two 2.5” drives (like VelociRaptors or the 2.5” WD Red’s), or 2.5” SSD’s, or a single thin 3.5” drive – all the while still leaving the ODD bay open for the Optical Disk Drive or one or two SSD’s! I can disconnect the drive cage SAS cable and attach a SFF-8087 to the system board giving me two SATA III ports (SATA cables 1 & 2 off the SFF-8087) and two SATA II ports (SATA cables 3 & 4 off the SFF-8087) all controlled by the HP Dynamic Smart Array B120i RAID Controller. The now free HP SAS cable to the drive cage could be attached to an add-in card (such as an HP P222) providing functionality for four 3.5” drives in the drive cage.

     

    The HP ProLiant Gen8 MicroServer is a fun machine to work with -- but the SGDM takes it to a whole new level! Thanks Schoondoggy!  In my opinion, if you have a Gen8 MicroServer -- you are going to want a Schoondoggy Gen8 Drive Mount.

     

     

     

    Background

     

    In early August, 2013, Schoondoggy announced in the HSS Forums that he had a prototype of a drive mounting bracket to enable him to mount two additional 2.5” drives in the recently introduced HP ProLiant Gen8 MicroServer. Many on the Forums were encouraged by Schoondoggy’s efforts to refine his design and bring his bracket to production. His idea would enable the option of two drives within the Gen8 case in addition to the main 4 drive bay and the ODD.

     

     

     

    clip_image005

     

    Figure 1 -- Schoondoggy's Prototype Drive Bracket for Gen8 MicroServer from HSS Forums

     

     

     

    At the Home Server Show Meetup 2013 Schoondoggy displayed his HP ProLiant Gen8 MicroServer prototype drive mounting bracket and I was amazed to see how he had fit the additional drives in the available space and came up with a cooling solution. This was one of the highlights of the Meetup for me and I took several pictures of Schoondoggy’s display which are included in the MeetUp 2013 Wrap Up Photos section.

     

     

     

    clip_image007

     

    Figure 2 -- Schoondoggy's Gen8 MicroServer Prototype Drive Bracket at MeetUp 2013

     

     

     

    Beta Test Preproduction Copy – Schoondoggy Gen8 Drive Mount

     

    Recently, Schoondoggy sent me a Best Test Copy of what I’ve decided to call in this write-up the Schoondoggy Gen8 Drive Mount (“SGDM”). I will now address my unboxing, installation, and testing of the SGDM.

     

    Unboxing

     

    clip_image009

     

    Figure 3 -- The SGDM Unboxed and displayed next to HP ProLiant Gen8 MicroServer

     

     

     

    The SGDM unboxing is recorded in the following video:

     

     

     

     

    clip_image011

     

    Figure 4 -- The Two Arrows show the Location to use the 2 Longer, Supplied, Screws to Attach the SGDM to the Gen8 MicroServer PSU

     

     

     

    clip_image013

     

    Figure 5 -- SGDM Attached to Gen8 MicroServer without Drives

     

     

     

    clip_image015

     

    Figure 6 -- Location of Mounting Holes for 2.5" Drives/SSDs

     

     

     

    clip_image017

     

    Figure 7 -- Location of Mounting Holes for Thin 3.5" Drive

     

     

     

    clip_image019

     

    Figure 8 -- Additional Parts Needed: 8 Drive/SSD screws & 8 Neoprene washers

     

     

     

    Additional Parts Needed:

    • 8 -- 2.5” Drive/SSD Mounting Screws (if mounting a 3.5” drive only 2 screws are necessary)
    • 8 – Insulated (Rubber or Neoprene) washers – I used 3/8” OD w 5/32” ID

     

     

    clip_image021

     

    Figure 9 -- Back of SGDM with 8 Drive Mount Holes Counter Sunk

     

     

     

    clip_image023

     

    Figure 10 -- Bit used to Counter Sink Drive Mount Holes -- work slowly and carefully and check often if hole is counter sunk enough

     

     

     

    Mounting 2.5” VelociRaptors (without Ice-Pack) to the SGDM and attaching the SGDM to the MicroServer

     

    Mounting Two 2.5” VelociRaptors is shown in the following video:

     

     

     

     

     

     

    clip_image025

     

    Figure 11 -- Note the Air Gap Created by using the Insulated Washers between the SGDM and the 2.5” drive (VelociRaptor in this case) -- Air Flow from the Blower in this Air Gap will help cool the VelociRaptor (Note that the screw holes to mount the drives to the SGDM have not been counter sunk yet in this photo)

     

     

     

    clip_image027

     

    Figure 12 -- 2.5" VelociRaptors attached to SGDM and screws have been counter sunk

     

     

     

    clip_image029

     

    Figure 13 -- The only Modification that was necessary on the SGDM was to use a Dremel to grind out the PSU Attachment holes towards the end of the tab to line up with the PSU mounting bracket holes -- future production units will have this corrected

     

     

     

    Mounting 2.5” SSD’s to the SGDM

     

    Mounting Two 2.5” SSD’s is shown in the following video:

     

     

     

     

    Mounting 3.5” Thin Hard Drive to the SGDM

     

    One 3.5” Thin Hard Drive can be mounted to the SGDM as shown in the following video:

     

     

     

     

    Power & Data Connection for Schoondoggy Gen8 Drive Mount (“SGDM”)

     

    Parts Used:

     

     

    clip_image031

     

    Figure 14 -- Parts for Connecting Power to Drives on SGDM

     

     

     

     

     

    Steps:

     

    1. Review the material on page 46 of the HP ProLiant MicroServer Gen8 Server Maintenance and Service Guide.

     

    clip_image032

     

    Figure 15 -- Page 46 of the HP ProLiant MicroServer Gen8 Server Maintenance and Service Guide

     

     

     

    2. Disconnect the 4 pin Molex connector from the PSU to the power cable underneath the ODD area frame.

     

    clip_image034

     

    Figure 16 -- the 4 pin Molex connector underneath the ODD area frame has been disconnected in this picture

     

     

     

    3. Between the now open connections attach a 4 pin Molex Y connector – Attach terminals A and B shown in Figure 14 above.

     

    clip_image036

     

    Figure 17 -- See Figure 14 above and attach terminal A and B

     

     

     

    4. On the extra free 4 pin Molex connection attach a 4 pin Molex to Molex pass through connection with a 2 wire Fan auxiliary connector.

     

    clip_image038

     

    Figure 18 -- See also Figure 14 above on how this connected

     

     

     

    5. On the free 4 pin Molex connection attach a 4 pin Molex Y to 2 SATA Power connectors

     

    clip_image040

     

    Figure 19 -- See also Figure 14 above on how this is connected

     

     

     

    6. Attach the SATA Power connectors to the drives attached to the SGDM

     

    clip_image042

     

    Figure 20 -- In Figure 14 above the SATA Power Connectors are labeled Terminals C & D

     

     

     

    7. Remove the Fan auxiliary connector (on 4 above) and attach 2 quick connect on the wires

     

    clip_image044

     

    Figure 21 -- in Figure 14 above the fan connector is labeled Terminal E

     

     

     

    clip_image046

     

    Figure 22 -- These are the connectors I used to attached the fan

     

     

     

    clip_image048

     

    Figure 23 -- Two connectors have been attached

     

     

     

    8. Attach 2 quick connect on the wires on the SGDM blower

     

    clip_image050

     

    Figure 24 -- Two Connectors have been attached to the Fan cables

     

     

     

    9. Place heavy duty Velcro on the frame to secure the aux blower

     

    clip_image052

     

    Figure 25 -- Measuring for length to cut Velcro too -- Velcro shown in Figure 14 and Next Figure

     

     

     

    clip_image054

     

    Figure 26 -- Heavy Duty Velcro used to attach Fan to MicroServer Frame

     

     

     

    clip_image055

     

    Figure 27 -- Velcro cut to size of Frame Attachment

     

     

     

    clip_image057

     

    Figure 28 -- Velcro Attached to Frame

     

     

     

    10. Attach the Quick Connects from the SGDM blower (see 8 above) to 7 above – be sure to match the wire color codes. Use electrical tape to cover the exposed connections.

     

    clip_image059

     

    Figure 29 -- Blower attached to Power via connectors and wrapped with electrical tape

     

     

     

    11. Position the SGDM blower. Secure to the Velcro.

     

    clip_image061

     

    Figure 30 -- Blower attached and positioned ot optimize around Drives and across side of PSU

     

     

     

    12. Disconnect the SAS fan out cable that goes to drive cage from System Board

     

    clip_image063

     

    Figure 31 -- HP SAS cable to Drive Cage SATA Ports to be disconnected from System Board

     

     

     

    13. Attach SFF-8087 to System Board

     

    clip_image065

     

    Figure 32 -- SFF-8087 to be attached to System Board where HP SAS cable had been attached

     

     

     

    clip_image067

     

    Figure 33 -- SFF-8087 Attached to System Board

     

     

     

    14. Attach SATA 1 & 2 from SFF-8087 to Drives on SGDM

     

    clip_image069

     

    Figure 34 -- SATA cables 1 & 2 from SFF-8087 attached to Drives on SGDM -- Note that these are the two SATA III (6Gbps) Ports from the System Board and are controllable from the HP Dynamic Smart Array B120i RAID Controller

     

     

     

    Tidy up the wiring and close the cover.

     

     

     

    iLO Stats

     

    clip_image071

     

    Figure 35 -- Temperature Graph via iLO with cover off and system up for several days

     

     

     

    clip_image073

     

    Figure 36 -- Temperature Graph via iLO – same as Figure 35 above except with Cover On.

     

     

     

    clip_image075

     

    Figure 37 -- iLO information on the two VelociRaptors attached to the SGDM in RAID0 for the OS Drive for Windows Server 2012

     

     

     

    clip_image077

     

    Figure 38 -- Windows Server 2012 installed with HP Intelligent Provisioning on HP ProLiant Gen8 MicroServer

     

     

     

    My System Configuration As-Built:

    • HP ProLiant Gen8 MicroServer Celeron G1610T
    • 16GB RAM – Kingston KVR1333D3E9SK2/16G
    • OS Drive: HP Dynamic Smart Array B120i RAID Controller – Logical RAID0 Drive made with two (2) physical drives VelociRaptor WD1500HLHX
    • OS: Windows Server 2012 Standard
    • Beta: Schoondoggy Gen8 Drive Mount (plus parts listed above to provide power and data to drives on the SGDM)

     

     

    clip_image079

     

    Figure 39 -- Loading Windows Server 2012 using Intelligent Provisioning

     

     

     

    Overall, I’m very pleased with the performance of the HP ProLiant Gen8 MicroServer with the Schoondoggy Gen8 Drive Mount. I am planning many more tests in the future using the SGDM in my Gen8 MicroServer.

     

     

     

    Questions?

     

    Join us in the HSS Forums with any questions and/or comments on the above and other threads.

     

     

     

    References

     

    HP MS G8 2.5” drive bracket prototype

     

    Meetup 2013 & Meetup 2013 Wrap UP

     

    MicroServer Blog Postings

     

    HP ProLiant MicroServer Gen8 Links

     

    Useful MicroServer Links & References

     

    MicroServer Hardware Links

     

     

     

     

    clip_image081



    Sign in to follow this  
    Followers 0

    Sign in to follow this  
    Followers 0


    User Feedback


    Hello, I'm wondering if it is possible to use this braket to mount a *not slim* 3.5 Drive? Do you know if it will fit?

    Share this comment


    Link to comment
    Share on other sites


    Create an account or sign in to comment

    You need to be a member in order to leave a comment

    Create an account

    Sign up for a new account in our community. It's easy!


    Register a new account

    Sign in

    Already have an account? Sign in here.


    Sign In Now